This page is part of archived documentation for openHAB 4.1. Go to the current stable version

# Omnik Inverter Binding

This binding reads metrics from Omnik Solar Inverters.

# Supported Things

All Omniksols are expected to function, provided they have the Wifi module. At moment of writing the Omniksol-3.0k-TL2 has been tested.

# Discovery

No autodiscovery available

# Thing Configuration

Config Description type Default
hostname The hostname or ip through which the inverter can be accessed string n/a
port TCP port through which the inverter listens on for incoming connections integer 8899
serial The serial of the wifi module. The Wifi module's SSID contains the number. This is the numerical part only, i.e. without AP_ integer n/a

# Channels

Channel Type Id Item Type Description
power Number:Power The instantaneous power generation for feed 1 to the grid, in Watt by default (deprecated; same as powerAC1)
powerAC1 Number:Power The instantaneous power generation for feed 1 to the grid, in Watt by default
powerAC2 Number:Power The instantaneous power generation for feed 2 to the grid, in Watt by default
powerAC3 Number:Power The instantaneous power generation for feed 3 to the grid, in Watt by default
voltageAC1 Number:ElectricPotential The voltage for feed 1 to the grid, in Volt by default
voltageAC2 Number:ElectricPotential The voltage for feed 2 to the grid, in Volt by default
voltageAC3 Number:ElectricPotential The voltage for feed 3 to the grid, in Volt by default
currentAC1 Number:ElectricCurrent The current for feed 1 to the grid, in ampere by default
currentAC2 Number:ElectricCurrent The current for feed 2 to the grid, in ampere by default
currentAC3 Number:ElectricCurrent The current for feed 3 to the grid, in ampere by default
frequencyAC1 Number:Frequency The frequrence of feed 1 of the grid, in hertz by default
frequencyAC2 Number:Frequency The frequrence of feed 2 of the grid, in hertz by default
frequencyAC3 Number:Frequency The frequrence of feed 3 of the grid, in hertz by default
currentPV1 Number:ElectricCurrent The current generation for input string 1, in ampere by default
currentPV2 Number:ElectricCurrent The current generation for input string 2, in ampere by default
currentPV3 Number:ElectricCurrent The current generation for input string 3, in ampere by default
voltagePV1 Number:ElectricPotential The voltage on input string 1, in volt by default
voltagePV2 Number:ElectricPotential The voltage on input string 2, in volt by default
voltagePV3 Number:ElectricPotential The voltage on input string 3, in volt by default
energyToday Number:Energy The amount of energy generated today, in kWh by default
energyTotal Number:Energy The total amount of energy generated, in kWh by default
temperature Number:Temperature The temperature from the sensor
hoursTotal Number:Time The total amount of running hours

# Full Example

# demo.things

Thing omnikinverter:omnik:70ecb4f0 "Solar Inverter" [ hostname="igen-wifi.lan",serial=604455290]

# demo.items

Number:Power OmnikInverterBindingThing_InstantaneousPower "Solar Power" <sun> {channel="omnikinverter:omnik:70ecb4f0:power"}
Number:Power OmnikInverterBindingThing_InstantaneousPower1 "Solar Power 1" <sun> {channel="omnikinverter:omnik:70ecb4f0:powerAC1"}
Number:Power OmnikInverterBindingThing_InstantaneousPower2 "Solar Power 2" <sun> {channel="omnikinverter:omnik:70ecb4f0:powerAC2"}
Number:Power OmnikInverterBindingThing_InstantaneousPower3 "Solar Power 3" <sun> {channel="omnikinverter:omnik:70ecb4f0:powerAC3"}
Number:Voltage OmnikInverterBindingThing_VoltagePV1 "PV Voltage 1" {channel="omnikinverter:omnik:70ecb4f0:voltagePV1"}
Number:Voltage OmnikInverterBindingThing_VoltagePV2 "PV Voltage 2" {channel="omnikinverter:omnik:70ecb4f0:voltagePV2"}
Number:Voltage OmnikInverterBindingThing_VoltagePV3 "PV Voltage 3" {channel="omnikinverter:omnik:70ecb4f0:voltagePV3"}
Number:Current OmnikInverterBindingThing_CurrentPV1 "PV current 1" {channel="omnikinverter:omnik:70ecb4f0:currentPV1"}
Number:Current OmnikInverterBindingThing_CurrentPV2 "PV current 2" {channel="omnikinverter:omnik:70ecb4f0:currentPV2"}
Number:Current OmnikInverterBindingThing_CurrentPV3 "PV current 3" {channel="omnikinverter:omnik:70ecb4f0:currentPV3"}
Number:Energy OmnikInverterBindingThing_TotalGeneratedEnergyToday "Solar Energy Today" <sun> {channel="omnikinverter:omnik:70ecb4f0:energyToday"}
Number:Energy OmnikInverterBindingThing_TotalGeneratedEnergy "Solar Energy Total" {channel="omnikinverter:omnik:70ecb4f0:energyTotal"}

# Sitemap

Text item=OmnikInverterBindingThing_InstantaneousPower
Text item=OmnikInverterBindingThing_InstantaneousPower1
Text item=OmnikInverterBindingThing_InstantaneousPower2
Text item=OmnikInverterBindingThing_InstantaneousPower3
Text item=OmnikInverterBindingThing_VoltagePV1
Text item=OmnikInverterBindingThing_VoltagePV2
Text item=OmnikInverterBindingThing_VoltagePV3
Text item=OmnikInverterBindingThing_CurrentPV1
Text item=OmnikInverterBindingThing_CurrentPV2
Text item=OmnikInverterBindingThing_CurrentPV3
Text item=OmnikInverterBindingThing_TotalGeneratedEnergyToday
Text item=OmnikInverterBindingThing_TotalGeneratedEnergy

# References

Based on the work of https://github.com/Woutrrr/Omnik-Data-Logger (opens new window)